Although the dose measurement system used in our study (FastCheck Mediland, Taoyuan City , Taiwan) is semi-quantitative, it allowed us to detect if the dose reached adequate values for disinfection and to repeat the application when the value was not satisfactory. However, each dose value exceeded the expected value. This demonstrates that the device was positioned correctly in order to avoid shadow areas, although it was necessary to properly place furniture and equipment to improve the irradiation of all surfaces. In the study conducted by Wong et al., the R-D Rapid Disinfector system (Steriliz, Rochester, NY, USA) was used in a tertiary care hospital to evaluate the incremental benefit of UV-C disinfection in isolation rooms after the discharge of infected patients. The employed robot used four detached sensors to directly measure the UV-C light [
Hospital environmental hygiene is a complex process because it is influenced by several variables, such as the type of surface, incorrect disinfectant contact times, excessive dilution of disinfectant solutions, and potential biocide/antibiotic cross-resistance. In addition, it has been shown that the use of contaminated cloths and/or solutions promotes the spread of microorganisms between different environments [
The cleaning procedure is not only dependent on the chemicals used but also on the personnel performing it. As reported by Toffollutti et al., there are differences between housekeeping and outsourcing cleaning staff in ensuring adequate levels of hygiene; outsourcing cleaning services was associated with a greater incidence of meticillin-resistant Staphylococcus aureus (MRSA) and worse patient perceptions of cleanliness [
In that regard, the World Health Organization has reiterated the importance of using this type of disinfection after the adoption of the standard protocol for sanitizing hospital rooms, but, during the COVID- pandemic, the use of UVC radiation was also proposed immediately after the patient has been discharged in order to reduce the risk of the cleaning staff being infected, who can then safely apply the standard protocol [
The UV-C disinfection robot (Mediland Enterprise Corporation, Taoyuan City, Taiwan) uses amalgam lamps (UV lamp NNI / XL Niederdruck VUV Strahler) and protective reflector technology to generate high-energy, broad-spectrum ultraviolet light (UV-C nm). The manufacturer of the lamps declares in the technical data sheet that the lamps have a filter that blocks radiation between nm, eliminating the possibility of producing ozone as a by-product of UV-C radiation. The UV-C device uses min disinfection cycles and multiple positions with minimal distances from high-touch surfaces. Due to the use of high-intensity UV-C radiation, the device must operate in unoccupied rooms. There are multi-motion sensors that shut off the device if any movement is detected inside the room being disinfected or if the door is accidentally opened. When the robot operates in accordance with these procedures, the manufacturer declares that the amalgam lamps produce no ozone gas and leave no toxic residues.