We are more than just a water pump company. Through our solutions and services, we touch millions and millions of people every day, without most even noticing. And with that comes great responsibility. A responsibility to respect, protect and advance the flow of water for people, businesses and the planet. Because at Grundfos, we believe that every drop contains infinite possibilities, and that water has the power to change the world.
The UV-C disinfection robot (Mediland Enterprise Corporation, Taoyuan City, Taiwan) uses amalgam lamps (UV lamp NNI / XL Niederdruck VUV Strahler) and protective reflector technology to generate high-energy, broad-spectrum ultraviolet light (UV-C nm). The manufacturer of the lamps declares in the technical data sheet that the lamps have a filter that blocks radiation between nm, eliminating the possibility of producing ozone as a by-product of UV-C radiation. The UV-C device uses min disinfection cycles and multiple positions with minimal distances from high-touch surfaces. Due to the use of high-intensity UV-C radiation, the device must operate in unoccupied rooms. There are multi-motion sensors that shut off the device if any movement is detected inside the room being disinfected or if the door is accidentally opened. When the robot operates in accordance with these procedures, the manufacturer declares that the amalgam lamps produce no ozone gas and leave no toxic residues.
Hospital environmental hygiene is a complex process because it is influenced by several variables, such as the type of surface, incorrect disinfectant contact times, excessive dilution of disinfectant solutions, and potential biocide/antibiotic cross-resistance. In addition, it has been shown that the use of contaminated cloths and/or solutions promotes the spread of microorganisms between different environments [
In the OT and ICU, where the limit for hygiene quality is defined by national guidelines, respectively, % (/) and % (/) of the surface samples resulted in being non-compliant after SOP. In the ward rooms, according to the standard reported in the literature, % (/) of the sampled sites resulted in being non-compliant. All of the samples were compliant after UV-C disinfection. In all of the settings, % (/) of the sampled points received a medium UV-C dose of mJ/cm
The cleaning procedure is not only dependent on the chemicals used but also on the personnel performing it. As reported by Toffollutti et al., there are differences between housekeeping and outsourcing cleaning staff in ensuring adequate levels of hygiene; outsourcing cleaning services was associated with a greater incidence of meticillin-resistant Staphylococcus aureus (MRSA) and worse patient perceptions of cleanliness [