Hospital lights and environmental disinfectants In Pakdasht ( Sale, implementation consultation )

Hospital lights and environmental disinfectants-1
Hospital lights and environmental disinfectants-2

Presentation of businesses
You can introduce your business services or products in this section.
For this purpose, be in touch with us.




The disinfection of the air with UV-C is performed by irradiating the upper-room air only, the whole room when unoccupied, or the air flowing inside the air-handling units. The study conducted by McGinn et al. demonstrated the feasibility of using a UV-C robotic system to disinfect both air and surfaces in a radiology environment, where it was two and four times faster than currently used chemical approaches [

Among the appliable strategies for the improvement of cleaning and disinfection practices are the use of new materials and/or disinfectants, the training and audit of operators, and the use of new automated technologies, which are becoming increasingly important. In particular, no-touch disinfection technologies have the great advantage of not being dependent on the operator, ensuring process repeatability. Furthermore, their effectiveness has been demonstrated even on sites that are difficult to reach with manual intervention. Their use complements but does not replace ordinary cleaning and disinfection protocols. In the past few years, ultraviolet disinfection systems have been widely investigated and used as a way to improve standard cleaning protocols. Currently, ultraviolet devices are automated in order to guarantee process repeatability and reduce human errors. The application of UV devices as an addition to traditional environmental cleaning has become increasingly common due to their effectiveness in reducing the environmental microbial burden in a shorter time compared to other technologies using chemical products [

Although the dose measurement system used in our study (FastCheck Mediland, Taoyuan City , Taiwan) is semi-quantitative, it allowed us to detect if the dose reached adequate values for disinfection and to repeat the application when the value was not satisfactory. However, each dose value exceeded the expected value. This demonstrates that the device was positioned correctly in order to avoid shadow areas, although it was necessary to properly place furniture and equipment to improve the irradiation of all surfaces. In the study conducted by Wong et al., the R-D Rapid Disinfector system (Steriliz, Rochester, NY, USA) was used in a tertiary care hospital to evaluate the incremental benefit of UV-C disinfection in isolation rooms after the discharge of infected patients. The employed robot used four detached sensors to directly measure the UV-C light [



( Sale, implementation consultation ) `s other In Pakdasht