The best ways to maintain and operate a boiler start with maintaining a regular schedule of reviewing reports and checklists to ensure proper equipment operation. Pressure, water temperature, and vent gas temperature reports should be recorded daily so that they can be used as a basic reference for troubleshooting system performance. More detailed checks and checks should be important to provide system performance. Without this, there may be gradual changes in system performance over time that are not clearly visible. Tips for achieving performance efficiency include, for example, daily, weekly, and monthly inspection reports that you can apply to the building. The following maintenance checklist is provided based on the methods used in this article.
Steel boilers, as their name implies, are made of steel and are usually made of horizontal cylinders. Steel boilers have a combustion chamber in which pipes are placed around this chamber. The pipes that are installed around the combustion chamber of steel boilers are made of a special alloy so that they do not burn or damage in the face of a direct flame. These pipes are called (fire pipes). Steel boilers are divided into friends from the point of view of heat transfer, which are as follows.
In commercial complexes, the boiler is very different in summer and winter, night and day, working days and weekends. Using a boiler can not apply this load difference well. When the heat generated by the boiler at the lowest ignition rate exceeds the heat required by the building, the boiler cycle will be interrupted. Starting and interrupting the cycle in the boiler is not efficient at all because, in each cycle, a pre-combustion discharge and a post-combustion discharge are performed to direct the heat out of the boiler. Also in the case of boilers that do not perform the adjustment operation, when the combustion efficiency is at its best, the cycle process does not allow the boiler to operate in the second boiler and the ignition rate is constant.
To increase the overall efficiency of the boiler, the heat released from the combustion process must be properly transferred into the fluid used. Any heat that is not transferred to the fluid is lost through the body of the boiler or the flue gas. The temperature of the gas inside the chimney is a good indicator of the heat transfer process and therefore efficiency. There are practical limitations to the low flue temperature. Its temperature will be higher than the fluid used in the boiler. In boilers that do not do distillation, the temperature should be high enough that water vapor does not distill in the exhaust chimney and clean the heat transfer surface in the distillation that causes corrosion. Condensing boilers that use natural gas are made and designed with accessories that are resistant to corrosion. Also, their chimney temperature can be less than . degrees Celsius. Trapping heat distillation increases efficiency by more than %.
Eng. Shamel, I wanted to thank you and CATEC team as well for taking time from your busy schedule to support and help Americana meat KSA on all utilities projects (steam boilers, thermal oil heaters, etc). I kNow some of the work wasn’t part of your normal responsibilities, but your assistance was invaluable in helping my company get everything done in a very timely manner. Your expertise and enthusiasm were both appreciated during a time which can be stressful for all concerned! We sincerely appreciate your efforts and thank all CATEC team