The role of the environment, particularly of high-touch surfaces in the patient&#x;s room (e.g., bedrails, over-bed tables, and call-buttons) and reusable care equipment that is moved between rooms, has been demonstrated to be fundamental in the transmission of healthcare-related infections. Together with standard precautions and the application of good practices in invasive procedures, environmental cleaning and disinfection represents one of the three pillars of infection risk prevention in healthcare settings.

Improving the cleaning and disinfection of high-touch surfaces is one of the core components of reducing healthcare-associated infections. The effectiveness of an enhanced protocol applying UV-C irradiation for terminal room disinfection between two successive patients was evaluated. Twenty high-touch surfaces in different critical areas were sampled according to ISO -, both immediately pre- and post-cleaning and disinfection standard operating protocol (SOP) and after UV-C disinfection ( sampling sites in each condition, in total). Dosimeters were applied at the sites to assess the dose emitted. A total of .% (/) of the sampling sites tested after SOP were positive, whereas only .% (/) were positive after UV-C. According to the national hygienic standards for health-care setting, .% (/) resulted in being non-compliant after SOP and only .% (/) were non-compliant after UV-C disinfection. Operation theaters was the setting that resulted in being less compliant with the standard limit (&#x; colony-forming unit/ cm

The UV-C disinfection robot (Mediland Enterprise Corporation, Taoyuan City, Taiwan) uses amalgam lamps (UV lamp NNI / XL Niederdruck VUV Strahler) and protective reflector technology to generate high-energy, broad-spectrum ultraviolet light (UV-C &#x; nm). The manufacturer of the lamps declares in the technical data sheet that the lamps have a filter that blocks radiation between &#x; nm, eliminating the possibility of producing ozone as a by-product of UV-C radiation. The UV-C device uses min disinfection cycles and multiple positions with minimal distances from high-touch surfaces. Due to the use of high-intensity UV-C radiation, the device must operate in unoccupied rooms. There are multi-motion sensors that shut off the device if any movement is detected inside the room being disinfected or if the door is accidentally opened. When the robot operates in accordance with these procedures, the manufacturer declares that the amalgam lamps produce no ozone gas and leave no toxic residues.



( implementation consultation ) `s other