The role of the environment, particularly of high-touch surfaces in the patients room (e.g., bedrails, over-bed tables, and call-buttons) and reusable care equipment that is moved between rooms, has been demonstrated to be fundamental in the transmission of healthcare-related infections. Together with standard precautions and the application of good practices in invasive procedures, environmental cleaning and disinfection represents one of the three pillars of infection risk prevention in healthcare settings.
In our study, we evaluated the efficacy of the UV-C treatment only on the reduction in mesophilic growth that mainly represents human contamination, but not on specific pathogens of interest; however, the reduction was very significant, suggesting that this system can easily eliminate pathogens as well. We have previously demonstrated that the adoption of an automated UV-C-disinfection robot in the enhancement of SOP in high-risk settings was successful in reducing pathogens on high-touch surfaces, improving the patients safety [
In that regard, the World Health Organization has reiterated the importance of using this type of disinfection after the adoption of the standard protocol for sanitizing hospital rooms, but, during the COVID- pandemic, the use of UVC radiation was also proposed immediately after the patient has been discharged in order to reduce the risk of the cleaning staff being infected, who can then safely apply the standard protocol [
Hospital environmental hygiene is a complex process because it is influenced by several variables, such as the type of surface, incorrect disinfectant contact times, excessive dilution of disinfectant solutions, and potential biocide/antibiotic cross-resistance. In addition, it has been shown that the use of contaminated cloths and/or solutions promotes the spread of microorganisms between different environments [
The UV-C disinfection robot (Mediland Enterprise Corporation, Taoyuan City, Taiwan) uses amalgam lamps (UV lamp NNI / XL Niederdruck VUV Strahler) and protective reflector technology to generate high-energy, broad-spectrum ultraviolet light (UV-C nm). The manufacturer of the lamps declares in the technical data sheet that the lamps have a filter that blocks radiation between nm, eliminating the possibility of producing ozone as a by-product of UV-C radiation. The UV-C device uses min disinfection cycles and multiple positions with minimal distances from high-touch surfaces. Due to the use of high-intensity UV-C radiation, the device must operate in unoccupied rooms. There are multi-motion sensors that shut off the device if any movement is detected inside the room being disinfected or if the door is accidentally opened. When the robot operates in accordance with these procedures, the manufacturer declares that the amalgam lamps produce no ozone gas and leave no toxic residues.