In our study, we evaluated the efficacy of the UV-C treatment only on the reduction in mesophilic growth that mainly represents human contamination, but not on specific pathogens of interest; however, the reduction was very significant, suggesting that this system can easily eliminate pathogens as well. We have previously demonstrated that the adoption of an automated UV-C-disinfection robot in the enhancement of SOP in high-risk settings was successful in reducing pathogens on high-touch surfaces, improving the patients safety [
In this hospital, cleaning services were outsourced. According to the contract and the cleaning and disinfection standard operating protocol (SOP), during terminal disinfection, the housekeeping staff applied a chlorine-based detergent, Antisapril Detergent %, Angelini, followed by a chlorine-based disinfectant (Deornet Clor (COSÌ, Forlì-Cesena, Italy), active chlorine mgr/L) on furniture surfaces and electromedical devices.
Hospital environmental hygiene is a complex process because it is influenced by several variables, such as the type of surface, incorrect disinfectant contact times, excessive dilution of disinfectant solutions, and potential biocide/antibiotic cross-resistance. In addition, it has been shown that the use of contaminated cloths and/or solutions promotes the spread of microorganisms between different environments [
Improving the cleaning and disinfection of high-touch surfaces is one of the core components of reducing healthcare-associated infections. The effectiveness of an enhanced protocol applying UV-C irradiation for terminal room disinfection between two successive patients was evaluated. Twenty high-touch surfaces in different critical areas were sampled according to ISO -, both immediately pre- and post-cleaning and disinfection standard operating protocol (SOP) and after UV-C disinfection ( sampling sites in each condition, in total). Dosimeters were applied at the sites to assess the dose emitted. A total of .% (/) of the sampling sites tested after SOP were positive, whereas only .% (/) were positive after UV-C. According to the national hygienic standards for health-care setting, .% (/) resulted in being non-compliant after SOP and only .% (/) were non-compliant after UV-C disinfection. Operation theaters was the setting that resulted in being less compliant with the standard limit ( colony-forming unit/ cm
These organisms belong to a group of carbapenem-resistant, gram-negative bacteria of national and international concern because of their implication as an emerging cause of severe healthcare-associated infections. In , the World Health Organization published the first global guidelines for the prevention and control of CRE-CRAB-CRPsA in healthcare facilities, which include environmental cleaning and disinfection as a key recommendation.