Sale Winding In Kharazmi Industrial City

Winding-1
Winding-2

Presentation of businesses
You can introduce your business services or products in this section.
For this purpose, be in touch with us.



For transformer winding machines, choose coils with a compact structure, small size and high compressive strength made with this type of equipment. To further improve productivity, we have increased the speed ratio of the automatic winder server from rad / min to rad / min. The wire row configuration is pulled from two ends to three ends. That is, you can wind three additional coils at once. In addition, select multiple sections ( more) to wind up. The axial clamp configuration has been improved and the bearing capacity of the payoff reels of each structure is controlled independently, so the take-up transmission lines are neatly arranged and the turns cannot be separated. It is symmetrical and the current intensity is evenly distributed throughout. In addition, it has an end insulation layer rewind mechanism and a transmission line tension mechanism. Computers need to preset various key parameters so that the coil inductance can be performed at once, greatly increasing the level of automation. It will be improved and the labor intensity of workers will be reduced. 

For the alarm setting of the self-winding machine, the system software can start the alarm according to the set alarm level. Also, depending on the level, various alarm shutdown methods are used to disconnect the automated inspection system, but if the main parameter setting is disconnected and a shutdown is required, the system software will stop the winding and the operator will Also decide whether to do it. For standard pneumatic tests, the system software sets up the original standard pneumatic test. If the working pressure is lower than the preset value, the system software will stop running and start rewinding after the standard air pressure responds.

The methods that are most successfully used employ time-of-pulse arrival, pulse shape analysis and the optimal selection of the measurement frequency range. Since the early days, great progress has been made with interpretation. Case studies from petrochemical industry machines are presented to show how machines with insulation  problems can be identified using both the trend in PD over time and the absolute magnitude of the PD. However, experience shows that the trend itself, as well as the absolute magnitude can sometimes give a misleading indication of the stator winding insulation condition.



( Sale ) `s other